double precision function dpmpar(i) integer i c ********** c c Function dpmpar c c This function provides double precision machine parameters c when the appropriate set of data statements is activated (by c removing the c from column 1) and all other data statements are c rendered inactive. Most of the parameter values were obtained c from the corresponding Bell Laboratories Port Library function. c c The function statement is c c double precision function dpmpar(i) c c where c c i is an integer input variable set to 1, 2, or 3 which c selects the desired machine parameter. If the machine has c t base b digits and its smallest and largest exponents are c emin and emax, respectively, then these parameters are c c dpmpar(1) = b**(1 - t), the machine precision, c c dpmpar(2) = b**(emin - 1), the smallest magnitude, c c dpmpar(3) = b**emax*(1 - b**(-t)), the largest magnitude. c c Argonne National Laboratory. MINPACK Project. November 1996. c Burton S. Garbow, Kenneth E. Hillstrom, Jorge J. More' c c ********** integer mcheps(4) integer minmag(4) integer maxmag(4) double precision dmach(3) equivalence (dmach(1),mcheps(1)) equivalence (dmach(2),minmag(1)) equivalence (dmach(3),maxmag(1)) c c Machine constants for the IBM 360/370 series, c the Amdahl 470/V6, the ICL 2900, the Itel AS/6, c the Xerox Sigma 5/7/9 and the Sel systems 85/86. c c data mcheps(1),mcheps(2) / z34100000, z00000000 / c data minmag(1),minmag(2) / z00100000, z00000000 / c data maxmag(1),maxmag(2) / z7fffffff, zffffffff / c c Machine constants for the Honeywell 600/6000 series. c c data mcheps(1),mcheps(2) / o606400000000, o000000000000 / c data minmag(1),minmag(2) / o402400000000, o000000000000 / c data maxmag(1),maxmag(2) / o376777777777, o777777777777 / c c Machine constants for the CDC 6000/7000 series. c c data mcheps(1) / 15614000000000000000b / c data mcheps(2) / 15010000000000000000b / c c data minmag(1) / 00604000000000000000b / c data minmag(2) / 00000000000000000000b / c c data maxmag(1) / 37767777777777777777b / c data maxmag(2) / 37167777777777777777b / c c Machine constants for the PDP-10 (KA processor). c c data mcheps(1),mcheps(2) / "114400000000, "000000000000 / c data minmag(1),minmag(2) / "033400000000, "000000000000 / c data maxmag(1),maxmag(2) / "377777777777, "344777777777 / c c Machine constants for the PDP-10 (KI processor). c c data mcheps(1),mcheps(2) / "104400000000, "000000000000 / c data minmag(1),minmag(2) / "000400000000, "000000000000 / c data maxmag(1),maxmag(2) / "377777777777, "377777777777 / c c Machine constants for the PDP-11. c c data mcheps(1),mcheps(2) / 9472, 0 / c data mcheps(3),mcheps(4) / 0, 0 / c c data minmag(1),minmag(2) / 128, 0 / c data minmag(3),minmag(4) / 0, 0 / c c data maxmag(1),maxmag(2) / 32767, -1 / c data maxmag(3),maxmag(4) / -1, -1 / c c Machine constants for the Burroughs 6700/7700 systems. c c data mcheps(1) / o1451000000000000 / c data mcheps(2) / o0000000000000000 / c c data minmag(1) / o1771000000000000 / c data minmag(2) / o7770000000000000 / c c data maxmag(1) / o0777777777777777 / c data maxmag(2) / o7777777777777777 / c c Machine constants for the Burroughs 5700 system. c c data mcheps(1) / o1451000000000000 / c data mcheps(2) / o0000000000000000 / c c data minmag(1) / o1771000000000000 / c data minmag(2) / o0000000000000000 / c c data maxmag(1) / o0777777777777777 / c data maxmag(2) / o0007777777777777 / c c Machine constants for the Burroughs 1700 system. c c data mcheps(1) / zcc6800000 / c data mcheps(2) / z000000000 / c c data minmag(1) / zc00800000 / c data minmag(2) / z000000000 / c c data maxmag(1) / zdffffffff / c data maxmag(2) / zfffffffff / c c Machine constants for the Univac 1100 series. c c data mcheps(1),mcheps(2) / o170640000000, o000000000000 / c data minmag(1),minmag(2) / o000040000000, o000000000000 / c data maxmag(1),maxmag(2) / o377777777777, o777777777777 / c c Machine constants for the Data General Eclipse S/200. c c Note - it may be appropriate to include the following card - c static dmach(3) c c data minmag/20k,3*0/,maxmag/77777k,3*177777k/ c data mcheps/32020k,3*0/ c c Machine constants for the Harris 220. c c data mcheps(1),mcheps(2) / '20000000, '00000334 / c data minmag(1),minmag(2) / '20000000, '00000201 / c data maxmag(1),maxmag(2) / '37777777, '37777577 / c c Machine constants for the Cray-1. c c data mcheps(1) / 0376424000000000000000b / c data mcheps(2) / 0000000000000000000000b / c c data minmag(1) / 0200034000000000000000b / c data minmag(2) / 0000000000000000000000b / c c data maxmag(1) / 0577777777777777777777b / c data maxmag(2) / 0000007777777777777776b / c c Machine constants for the Prime 400. c c data mcheps(1),mcheps(2) / :10000000000, :00000000123 / c data minmag(1),minmag(2) / :10000000000, :00000100000 / c data maxmag(1),maxmag(2) / :17777777777, :37777677776 / c c Machine constants for the VAX-11. c c data mcheps(1),mcheps(2) / 9472, 0 / c data minmag(1),minmag(2) / 128, 0 / c data maxmag(1),maxmag(2) / -32769, -1 / c c Machine constants for IEEE machines. c data dmach(1) /2.22044604926d-16/ data dmach(2) /2.22507385852d-308/ data dmach(3) /1.79769313485d+308/ c dpmpar = dmach(i) return c c Last card of function dpmpar. c end